Products Information
As a professional solenoid valve manufacturer, we are engaged in researching, developing, manufacturing and selling various solenoid valves, mainly products are VM series gas Solenoid Valve, VS series gas valve, pulse solenoid valve, fuel pressure reducing valve, ZCT Direct acting Solenoid Valve, ZCT Pilot Based Diaphragm Solenoid Valve, MQF Fuel Gas Solenoid Valve, DF3 2 Position Solenoid Valve, 2W Direct Acting Solenoid Valve, and so on. We can design solenoid valves according to clients' requirement, from size to function, solenoid valves for gas, water, Co2, air, etc. 2 way solenoid valves, 3 way solenoid valve, or even more. 12v solenoid valve, 24v solenoid valve, a full range of voltage types for you. More new solenoid valves can be found from our website.
Model |
Drift diameter (mm) |
Technology |
Voltage (v) |
Overall dimension |
Connect dimension |
Body material |
||
Length |
Height |
|||||||
VM-20 |
20 |
Pressure scope: 0~360mbar |
Slow open>7seconds Quick close<1second Working media: Water gas,gas, nature gas petroleum,liquid gas ,mashgas Media temperature: 0~60°C |
AC220 110 36 24 12 DC220 36 24 12 |
94 |
234 |
Internal threadG3/4" |
Aluminum alloy |
VM-25 |
25 |
94 |
234 |
Internal threadG1" |
||||
VM-32 |
32 |
152 |
290 |
Internal threadG11/4" |
||||
VM-40 |
40 |
152 |
290 |
Internal threadG11/2" |
||||
VM-50 |
50 |
155 |
290 |
Internal threadG2" |
||||
VM-65 |
65 |
0~200mbar |
305 |
430 |
flank4-Φ18×Φ145 |
|||
VM-80 |
80 |
305 |
430 |
flank8-Φ18×Φ160 |
Technical specification:
Pipe sizes 1000 series
Inlet an outlet 3/8’’ up to 3’’ internal parallel pipe thread according to ISO7-1
Pipe sizes 3000 series
Flanged connection DN65,DN100 according to PN16 ISO7005-1
Torsion and bending stress
Pipe connections meet group 2 according to EN161 requirements.
Ambient temperature
-15…60°C
Supply voltage:
220…240Vac,50/60Hz
110Vac,50/60Hz
24…36Vdc
The applicable voltage is led to the solenoid coil via a rectifying circuit
Maximum operating pressure
Rp3/8…21/2’’ types200 and 360mbar
Rp3’’..4’’types 200 mbar
Electrical connection
Plug connection according to PG11
Coil insulation solenoid valves
Insulation material according to class F
Operational voltage range
The gas valve will function satisfactory between 85% and 110% of rated voltage
Enclosure
IP54,unless otherwise specified
Strainer
A strainer is incorporated in the gas valve
Installation warning
Take care that installer is a trained experienced service man
Turn off gas supply before starting installation.
Disconnect power supply to prevent electrical shock and/or equiment damage
Mounting position
The gas valve can be mounted plus or minus 90 degree from the vertical
Mounting location
The distance between the gas valve and the wall/ground,must be at least 30cm
Warning
The outlet of a pressure relief valve must always be connected to the open atmosphere
Main gas connection theaded valve
Take care that dirt can not enter the gas valve during handing
Ensure the gas flows in the same direction as the arrow on the housing of the gas valve
Use a sound taper fiting with thread according to ISO 7-1(bs21,DIN2999) or apiece of new properly reamed pipe, free from swart
Do not thread or tighten the pipe or pipe fitting too far.otherwise valve distortion and malfunction could result
Apply a moderate amount of good quality thread compound to the pipe or fitting only, leaving the two end threads bare, pife tape may be used as an alternative
In order to tighten the pipe in the valve, do not use the actuator as a lever but use a suitable operating on the wrench boss
Main gas connection flanged valves
Take care that dirt cannot enter the gas vavle during hangding
Ensure the gas flows in the same direction as the arrow on the housing of the gas valve
Ensure that the inlet and outlet flanges are in line and separated from each enough to allow the valve to be mounted between them without damaging the gasket
Place gasket if necessary ,grease it slightly to keep it in place
Mount gas valve between flanges using the bolts for each flange
Warning
tightness test after installation
Spray all pipe connection and gaskets with a good quality gas leak detection spray
Star the application and check for bubbles. If a leak foud in a pipe connection remake the joint
A gasket leak can usually be stopped by tightening the mounting screws.Otherwise replace the gas valve
Caution
Switch off power supply before making electrical connections
Take care that wiring is accordance with local regulations
Use lead wire which can withstand105 degree ambient
The electrical ON/OFF operate is provided with a terminal block for electrical connections